Become a Readings Member to make your shopping experience even easier. Sign in or sign up for free!

Become a Readings Member. Sign in or sign up for free!

Hello Readings Member! Go to the member centre to view your orders, change your details, or view your lists, or sign out.

Hello Readings Member! Go to the member centre or sign out.

Calibration Methods for Reproducible and Comparable Electromagnetic Partial Discharge Measurements in Power Transformers
Paperback

Calibration Methods for Reproducible and Comparable Electromagnetic Partial Discharge Measurements in Power Transformers

$76.99
Sign in or become a Readings Member to add this title to your wishlist.

This title is printed to order. This book may have been self-published. If so, we cannot guarantee the quality of the content. In the main most books will have gone through the editing process however some may not. We therefore suggest that you be aware of this before ordering this book. If in doubt check either the author or publisher’s details as we are unable to accept any returns unless they are faulty. Please contact us if you have any questions.

The reliability of electrical energy networks depends on the quality and availability of their electrical equipment, e.g., power transformers. Local failures inside their insulation can lead to breakdowns resulting in high outage and penalty costs. To prevent these destructive events, power transformers are tested for partial discharge (PD) activity in a routine test before shipment. Furthermore, PD activity can be evaluated as a diagnostic measurement on-site (on-line or off-line) or be constantly monitored during service using the ultra-high frequency (UHF) method. In this thesis, a calibration procedure is proposed for the UHF method used in power transformers, which is lacking so far. The calibration process is required to ensure both reproducibility and comparability of UHF measurements. Only a calibrated UHF measurement procedure can be deemed reliable and eventually be introduced to supplement in (site-)acceptance tests of power transformers. The proposed calibration method considers two factors: The influence of the UHF sensors’ sensitivity and that of the UHF instrument characteristics, including accessories like cables, pre-amplifier, etc. The UHF instruments’ influence is corrected by using a defined and invariable test signal as a reference for all recording devices comparable to the calibration method used in IEC 60270 for electrical PD measurement. The sensitivity of the UHF sensor is addressed by a characterization of UHF sensors using the antenna factor (AF) measured in a special reproducible setup, i.e., a GTEM cell. In this thesis, a self-built GTEM cell is presented, which is oil-filled to address the environmental conditions inside a transformer where the sensor will be used. With such a cell, influences on the AF of UHF sensors are investigated, and it is shown that sensor sensitivities measured in an air-filled cell can be corrected to the oil environment. A practical evaluation of the proposed calibration procedure is performed in a laboratory

Read More
In Shop
Out of stock
Shipping & Delivery

$9.00 standard shipping within Australia
FREE standard shipping within Australia for orders over $100.00
Express & International shipping calculated at checkout

MORE INFO
Format
Paperback
Publisher
Books on Demand
Date
20 November 2020
Pages
130
ISBN
9783752628180

This title is printed to order. This book may have been self-published. If so, we cannot guarantee the quality of the content. In the main most books will have gone through the editing process however some may not. We therefore suggest that you be aware of this before ordering this book. If in doubt check either the author or publisher’s details as we are unable to accept any returns unless they are faulty. Please contact us if you have any questions.

The reliability of electrical energy networks depends on the quality and availability of their electrical equipment, e.g., power transformers. Local failures inside their insulation can lead to breakdowns resulting in high outage and penalty costs. To prevent these destructive events, power transformers are tested for partial discharge (PD) activity in a routine test before shipment. Furthermore, PD activity can be evaluated as a diagnostic measurement on-site (on-line or off-line) or be constantly monitored during service using the ultra-high frequency (UHF) method. In this thesis, a calibration procedure is proposed for the UHF method used in power transformers, which is lacking so far. The calibration process is required to ensure both reproducibility and comparability of UHF measurements. Only a calibrated UHF measurement procedure can be deemed reliable and eventually be introduced to supplement in (site-)acceptance tests of power transformers. The proposed calibration method considers two factors: The influence of the UHF sensors’ sensitivity and that of the UHF instrument characteristics, including accessories like cables, pre-amplifier, etc. The UHF instruments’ influence is corrected by using a defined and invariable test signal as a reference for all recording devices comparable to the calibration method used in IEC 60270 for electrical PD measurement. The sensitivity of the UHF sensor is addressed by a characterization of UHF sensors using the antenna factor (AF) measured in a special reproducible setup, i.e., a GTEM cell. In this thesis, a self-built GTEM cell is presented, which is oil-filled to address the environmental conditions inside a transformer where the sensor will be used. With such a cell, influences on the AF of UHF sensors are investigated, and it is shown that sensor sensitivities measured in an air-filled cell can be corrected to the oil environment. A practical evaluation of the proposed calibration procedure is performed in a laboratory

Read More
Format
Paperback
Publisher
Books on Demand
Date
20 November 2020
Pages
130
ISBN
9783752628180