Become a Readings Member to make your shopping experience even easier. Sign in or sign up for free!

Become a Readings Member. Sign in or sign up for free!

Hello Readings Member! Go to the member centre to view your orders, change your details, or view your lists, or sign out.

Hello Readings Member! Go to the member centre or sign out.

Der Fixateur Externe an Der Tibia
Paperback

Der Fixateur Externe an Der Tibia

$138.99
Sign in or become a Readings Member to add this title to your wishlist.

This title is printed to order. This book may have been self-published. If so, we cannot guarantee the quality of the content. In the main most books will have gone through the editing process however some may not. We therefore suggest that you be aware of this before ordering this book. If in doubt check either the author or publisher’s details as we are unable to accept any returns unless they are faulty. Please contact us if you have any questions.

Mechanik und Festigkeitslehre spielen in der Entwicklung des Fixateur exteme eine wesentliche Rolle. Obwohl es bis heute keine objektivierbare klinisch relevante Beurteilungsgrundlage gibt, wieviel Stabilitiit bzw. Steifig- keit bei der extemen Frakturstabilisierung erforderlich, oder wieweit diese erwiinscht ist, wird die Glite eines Fixateur-exteme-Typs an dessen Stabilisie- rungsf3higkeit gemessen. Stabilitiit wird unbestritten als ein wesentlicher Faktor der Infektionsprophylaxe bei offenen Frakturen und der Behandlung einer infizierten Fraktur oder Pseudarthrose angesehen. Flir die vorliegende Arbeit hat ebenfalls die Frage nach moglichst groBer Stabilitiit insbesondere fUr Fraktursituationen ohne knocheme Abstlitzung eine Rolle gespielt. AnlaB fUr die vorliegende Arbeit war eine klinische Erfahrung, niimlich daB Frakturen ohne knocheme Abstlitzung mit Hilfe der von der Arbeits- gemeinschaft flir Osteosynthesefragen (AO) vorgeschlagenen Montageformen des Fixateur externe nicht ausreichend stabilisiert werden konnten. Wissend urn die verschiedenen Schwachpunkte einer Fixateur-exteme-Osteosynthese wurde bei den mechanischen Untersuchungen der Montageform besondere Aufmerksamkeit geschenkt. Bei den guten klinischen Ergebnissen mit der neuentwickelten dreidimensionalen verstrebten und vorgespannten Fixateur- exteme-Montage scheint es an der Zeit, alle mechanischen Untersuchungser- gebnisse in dieser Form zu verOffentlichen und gleichzeitig Richtlinien flir eine korrekte Montage des neuen Typs aufzustellen. Mein Dank gilt in erster Linie meinem Chef Herm Prof. Dr. G. Hierholzer fUr dessen unentbehrliche Untersttitzung und Herrn Prof. Dr. Ing. K.H. Roik und dessen Mitarbeitem, Herm Dr. Ing. Hanenkamp und Herm Dr. Ing. Hartmann, yom Institut flir konstruktiven Ingenieurbau der Ruhr-Universitat Bochum, die die exakte Durchftihrung der Versuche und Berechnungen er- mOglichten.

Read More
In Shop
Out of stock
Shipping & Delivery

$9.00 standard shipping within Australia
FREE standard shipping within Australia for orders over $100.00
Express & International shipping calculated at checkout

MORE INFO
Format
Paperback
Publisher
Springer-Verlag Berlin and Heidelberg GmbH & Co. KG
Country
Germany
Date
1 June 1981
Pages
88
ISBN
9783540106654

This title is printed to order. This book may have been self-published. If so, we cannot guarantee the quality of the content. In the main most books will have gone through the editing process however some may not. We therefore suggest that you be aware of this before ordering this book. If in doubt check either the author or publisher’s details as we are unable to accept any returns unless they are faulty. Please contact us if you have any questions.

Mechanik und Festigkeitslehre spielen in der Entwicklung des Fixateur exteme eine wesentliche Rolle. Obwohl es bis heute keine objektivierbare klinisch relevante Beurteilungsgrundlage gibt, wieviel Stabilitiit bzw. Steifig- keit bei der extemen Frakturstabilisierung erforderlich, oder wieweit diese erwiinscht ist, wird die Glite eines Fixateur-exteme-Typs an dessen Stabilisie- rungsf3higkeit gemessen. Stabilitiit wird unbestritten als ein wesentlicher Faktor der Infektionsprophylaxe bei offenen Frakturen und der Behandlung einer infizierten Fraktur oder Pseudarthrose angesehen. Flir die vorliegende Arbeit hat ebenfalls die Frage nach moglichst groBer Stabilitiit insbesondere fUr Fraktursituationen ohne knocheme Abstlitzung eine Rolle gespielt. AnlaB fUr die vorliegende Arbeit war eine klinische Erfahrung, niimlich daB Frakturen ohne knocheme Abstlitzung mit Hilfe der von der Arbeits- gemeinschaft flir Osteosynthesefragen (AO) vorgeschlagenen Montageformen des Fixateur externe nicht ausreichend stabilisiert werden konnten. Wissend urn die verschiedenen Schwachpunkte einer Fixateur-exteme-Osteosynthese wurde bei den mechanischen Untersuchungen der Montageform besondere Aufmerksamkeit geschenkt. Bei den guten klinischen Ergebnissen mit der neuentwickelten dreidimensionalen verstrebten und vorgespannten Fixateur- exteme-Montage scheint es an der Zeit, alle mechanischen Untersuchungser- gebnisse in dieser Form zu verOffentlichen und gleichzeitig Richtlinien flir eine korrekte Montage des neuen Typs aufzustellen. Mein Dank gilt in erster Linie meinem Chef Herm Prof. Dr. G. Hierholzer fUr dessen unentbehrliche Untersttitzung und Herrn Prof. Dr. Ing. K.H. Roik und dessen Mitarbeitem, Herm Dr. Ing. Hanenkamp und Herm Dr. Ing. Hartmann, yom Institut flir konstruktiven Ingenieurbau der Ruhr-Universitat Bochum, die die exakte Durchftihrung der Versuche und Berechnungen er- mOglichten.

Read More
Format
Paperback
Publisher
Springer-Verlag Berlin and Heidelberg GmbH & Co. KG
Country
Germany
Date
1 June 1981
Pages
88
ISBN
9783540106654