Become a Readings Member to make your shopping experience even easier. Sign in or sign up for free!

Become a Readings Member. Sign in or sign up for free!

Hello Readings Member! Go to the member centre to view your orders, change your details, or view your lists, or sign out.

Hello Readings Member! Go to the member centre or sign out.

Microautoradiography and Electron Probe Analysis: Their Application to Plant Physiology
Paperback

Microautoradiography and Electron Probe Analysis: Their Application to Plant Physiology

$276.99
Sign in or become a Readings Member to add this title to your wishlist.

This title is printed to order. This book may have been self-published. If so, we cannot guarantee the quality of the content. In the main most books will have gone through the editing process however some may not. We therefore suggest that you be aware of this before ordering this book. If in doubt check either the author or publisher’s details as we are unable to accept any returns unless they are faulty. Please contact us if you have any questions.

In biological literature, several definitions of quantitative autoradio graphy are given. The term is defined as either the determination and com parison of the density of silver grains above various structures or under varying conditions, or the determination of absolute quantities of radio activity. In both these cases, photometric measurement serves for more rapid and more exact evaluation of grain densities than would be possible by visual counting of the grains. The equipment generally used for the photometric measurement of silver grains consists of a microscope, a photocell, an electronic amplifier system and a display unit. Grains can be made accessible to photometric evaluation by various kinds of microscopic illumination: 1. Substage bright-field illumination. 2. Substage dark-field illumination. 3. Incident dark-field illumination. 4. Vertical bright-field illumination. With all these types of illumination, the relationship between the luminous flux I absorbed by the film, scattered into the objective and reflected or diffracted, and the flux 10 which is not affected by the film is used as a measure of grain density. Since these are differential measurements, the light beam I transmitted by the film is in itself a measure of grain density if the luminous flux 10 incident on the grains is kept constant. This approach has been used in a large number of measuring setups.

Read More
In Shop
Out of stock
Shipping & Delivery

$9.00 standard shipping within Australia
FREE standard shipping within Australia for orders over $100.00
Express & International shipping calculated at checkout

MORE INFO
Format
Paperback
Publisher
Springer-Verlag Berlin and Heidelberg GmbH & Co. KG
Country
Germany
Date
28 December 1972
Pages
242
ISBN
9783540059509

This title is printed to order. This book may have been self-published. If so, we cannot guarantee the quality of the content. In the main most books will have gone through the editing process however some may not. We therefore suggest that you be aware of this before ordering this book. If in doubt check either the author or publisher’s details as we are unable to accept any returns unless they are faulty. Please contact us if you have any questions.

In biological literature, several definitions of quantitative autoradio graphy are given. The term is defined as either the determination and com parison of the density of silver grains above various structures or under varying conditions, or the determination of absolute quantities of radio activity. In both these cases, photometric measurement serves for more rapid and more exact evaluation of grain densities than would be possible by visual counting of the grains. The equipment generally used for the photometric measurement of silver grains consists of a microscope, a photocell, an electronic amplifier system and a display unit. Grains can be made accessible to photometric evaluation by various kinds of microscopic illumination: 1. Substage bright-field illumination. 2. Substage dark-field illumination. 3. Incident dark-field illumination. 4. Vertical bright-field illumination. With all these types of illumination, the relationship between the luminous flux I absorbed by the film, scattered into the objective and reflected or diffracted, and the flux 10 which is not affected by the film is used as a measure of grain density. Since these are differential measurements, the light beam I transmitted by the film is in itself a measure of grain density if the luminous flux 10 incident on the grains is kept constant. This approach has been used in a large number of measuring setups.

Read More
Format
Paperback
Publisher
Springer-Verlag Berlin and Heidelberg GmbH & Co. KG
Country
Germany
Date
28 December 1972
Pages
242
ISBN
9783540059509